Skip to content
FAM Plumbing

Water Tank Installation & Repair in Dubai

A water tank only looks simple from the outside. Inside, a float valve decides when it fills, an overflow decides what happens when that fails, a vent decides what gets in, and the outlet decides whether the water stays fresh. FAM Plumbing installs and repairs water tanks in villas, flats, offices and shops across Dubai. We size the tank from your real consumption, fit it with the pipework it needs, and repair the faults that make tanks overflow, run empty or leak.

  • Workmanship guarantee
  • Open 24/7
Rooftop sectional GRP tank with a ladder next to a chiller unit

Water tank installation and repair in Dubai: what we do

The jobs fall into five groups.

  • New tank installation. A ground, roof or in-building tank, sized, positioned and connected.
  • Tank replacement. Taking out an old or damaged tank and fitting a new one.
  • Float valve and overflow repair. Tanks that overflow, never fill, fill noisily or run down the overflow pipe.
  • Leak finding and tank repair. Cracks, weeping seams, leaking fittings and failed linings.
  • Upgrades. Adding a screened vent, a proper overflow, isolation valves, a drain, level indication or a second tank.
  • Emergency visits. We answer calls and send a plumber 24 hours a day, 7 days a week, and we do not promise an arrival time.

Some neighbouring topics have their own pages. Cleaning and disinfecting a tank is on our water tank cleaning page. Pumps that draw from a tank are on our booster pump page. Weak pressure at the tap is on our low water pressure page.

How big should the tank be?

The right size comes from how much water you use and how long you want the tank to cover. A tank that is too small runs out when the supply is interrupted. A tank that is too big holds water for a long time, and standing water loses quality.

Step 1: Find your daily use

The most reliable number is your own. Look at a recent water bill, which shows consumption for the billing period. Check the unit printed on the bill, divide the total by the number of days, and you have a daily figure for your property. Use a period that reflects normal use, and be careful with months that include a visitor surge, a pool fill or heavy irrigation.

If you have no bill, such as for a new build, we work from the number of people, the fittings and any garden or pool, and we say plainly that it is an estimate.

Step 2: Choose the days of cover

Decide how long the tank should last if the supply stops or the pump is out. This is a choice, not a rule. One day of cover is a common starting point for a home. A property that cannot go without water, such as a restaurant or a clinic, may want more.

Step 3: Multiply, then add a margin

Tank volume is daily use multiplied by the days of cover, plus a margin for growth and for the volume that should stay in the tank.

Worked example. A villa shows 24,000 litres of use over a 30-day bill, which is 800 litres a day. The owners want one day of cover and a 25 percent margin.

  • Daily use: 24,000 ÷ 30 = 800 litres.
  • One day of cover: 800 litres.
  • Margin of 25 percent: 800 × 1.25 = 1,000 litres.

A tank of about 1,000 litres would meet that need. Two tanks in sequence, such as a ground tank and a roof tank, split the total between them. The figures in this example are illustrative, to show the method.

Why bigger is not safer

A tank much larger than the daily use fills slowly and turns over slowly. Water that sits loses its disinfectant residual and can pick up growth. Good practice is to place the outlet low on the side opposite the inlet, so that the water mixes and does not stagnate or short-circuit. Over-sizing works against that. We aim for a size that covers the days you want without leaving water to stand for weeks.

Things that change the answer

  • Irrigation and pool top-ups, which add a large and seasonal load.
  • Pump draw, because a pump pulling flat out empties a small tank quickly. A tank-fed pump needs enough volume to run without starving, as our booster pump page explains.
  • Two tanks. A ground tank holds the reserve and a roof tank feeds the taps, and the two are sized together.
  • The supply. A supply that is slow to refill needs a bigger tank than one that refills quickly.
  • Space and weight. Water weighs 1 kilogram per litre, so a full 5,000-litre tank puts 5 tonnes of water, plus its own weight, on whatever carries it.

Tank types and materials

Tanks differ in where they sit and what they are made of. The right choice depends on the site, the access and the budget.

TypeWherePoints to know
Underground (ground) tankBelow a garden, driveway or basementProtected from sun, reached by a hatch, needs a pump to lift water
Roof tankOn a roof or raised platformFeeds taps by gravity. The roof has to carry the weight
In-building tank or plant-room tankInside a service roomKeeps the tank out of the sun and weather. Needs room for access
Break tankBetween the supply and a booster setGives the pump a reserve to draw from
MaterialWhat it isPoints to know
Polyethylene (plastic)Moulded plastic tank in a single pieceLight and easy to move into place. Sizes are limited by what can be moulded and carried
GRP (glass-reinforced plastic)Fibreglass panels or moulded shellsCan be made in large sizes. Sectional tanks are bolted together on site
ConcreteCast in placeBuilt to size and shape on site. May be lined
Stainless steelWelded or panel constructionSmooth surface. Costs more

We do not rank these, because the best material depends on the site. Whatever the material, it must be suitable for drinking water, and a drinking-water tank must be designed and built so that it prevents contamination.

Choosing between one tank and two

A single roof tank is the simplest arrangement, and a single ground tank with a pump to the taps is the next. Two tanks, a ground tank feeding a roof tank by a transfer pump, give more storage and a gravity feed to the taps. They also add a pump, a float switch and more places for faults. We recommend by property, not by default.

Where the tank goes

Siting a tank is half the job. A good tank in a poor place gives trouble for years.

Weight and support

A full tank is heavy. For a roof tank, a structural check of the roof or platform comes first. For an underground tank, the base should be level and firm so the tank sits evenly.

Heat and light

Light grows algae, and heat warms the water. A tank in direct sun, on a roof without shade, is exposed to both. A shaded position, an opaque tank and a sealed cover cut both problems.

Access for cleaning and inspection

A tank that cannot be reached cannot be cleaned. We leave room to open the hatch, reach the float valve and get a person or equipment in.

Underground tanks

Underground tanks bring their own questions.

  • Cover and seal. A tight, lockable cover keeps out soil, rain and surface water. Drinking-water tanks and their overflow tanks are meant to be covered.
  • Traffic. A tank under a driveway has to carry the load of vehicles above it.
  • Ground water. An empty tank in wet ground can be pushed upward. We check the ground conditions on a site where the water table is high.
  • Ventilation. The tank needs a vent, with a screen, that cannot take in surface water.
  • Pump position. The pump should be close and below or at the tank's outlet, where possible.

Roof tanks

  • A shaded, level, strong base.
  • Access by a fixed ladder or a safe route, not an improvised climb.
  • Protection from wind, so a light plastic tank does not shift when empty.
  • Overflow routed safely, so it does not run down a facade or into a neighbour's balcony.

Approval in flats

In a building, a tank is a shared system. Tank work needs management approval. Ask first. Tell us what your building asks for and we work to it.

Rooftop GRP water tank with a cleaning brush and a hose beside it

Fittings every tank needs

A tank is only as good as its connections. This is what a tank should have.

FittingWhat it doesNotes
Overflow or warning pipeCarries water away if the float valve fails, and shows that it hasSized larger than the inlet can supply, with a screen
Screened ventLets air in and out as the level changesKeeps insects and light out
OutletTakes water to the taps or pumpSet low, on the opposite side to the inlet where possible, to encourage mixing
Drain or washoutEmpties the tank for cleaning and repairLow point of the tank
Cover or lidKeeps out contaminationSealed, and lockable where the tank is outside
Level indicationShows how full the tank isA sight tube, gauge or electronic indicator
Access hatchLets people in and equipment outSized for the task
Isolation valvesClose the inlet and outlet for serviceOn both, within reach

We use this as a checklist, and we follow the building's requirements.

The overflow route

An overflow that ends somewhere unsafe is a fault waiting to happen. A visible overflow is also useful: when it drips, you know the float valve has failed.

The float valve

The float valve is the most important small part on the tank. It closes the inlet when the water reaches the set level. When it works, nobody notices it. When it fails, the tank overflows or runs low.

We fit a float valve rated for the supply pressure, and we set the shut-off level below the overflow. Setting it too high leaves no margin, so a small fault turns into a flood.

How a tank is installed

Every site differs, but the sequence is much the same.

  1. Survey. We check the site, the access, the base, the pipework and the existing connections. The visit fee is AED 50 + VAT, credited if the work goes ahead.
  2. Size and agree. We set the capacity, the tank type and the fittings, and agree a price.
  3. Permissions. In a building, management approval.
  4. Base. A level, strong base or support, built or checked.
  5. Place the tank. Craned, carried or built in place, depending on the type.
  6. Connect the inlet. Float valve and an isolation valve, with the shut-off level set.
  7. Connect the outlet. Isolation valve, strainer if needed, and pipework to the taps or pump.
  8. Connect the overflow, warning and vent. With screens, falling pipes and a safe discharge.
  9. Connect the drain.
  10. Fit the cover and hatch.
  11. Fill and test. See below.
  12. Hand over. We show you the valves, the float and the overflow, and give you the details.

Testing and commissioning

A new tank is tested before it goes into service.

  • Leak test. Fill the tank to the working level, mark the waterline, and watch for a drop over a day. A covered tank loses very little to evaporation over a day, so a clear drop points to a leak.
  • Float valve test. Check it shuts off at the set level, with a clear margin below the overflow.
  • Overflow test. Confirm that the overflow pipe discharges where intended and that the screen is in place.
  • Pump test, if there is a pump, including its low-level cut-out. See our booster pump page.
  • Clean and disinfect before use. Our water tank cleaning page explains the process.
  • Test the water, if the building or your contract needs it.

Float valve and overflow repair

A tank that overflows or never fills may have a float valve problem. The table is our own guide, so match what you see to it.

What you seePossible causeThe fix
Water runs out of the overflow pipe all the timeThe float valve is not shutting off: a worn seat or seal, grit in the valve, a bent arm, a float that has taken in water, or a level set too highClean the valve, reset the level, or replace the valve
Tank overflows only now and thenA valve that sticks, or a rise in supply pressureReplace the valve. Check the pressure
Tank never fills, or fills very slowlyA closed or partly closed inlet valve, a blocked strainer, a float arm snagged on something, a worn valve, or a supply problemOpen the valve, clean the strainer, free the arm, replace the valve, check the supply
Tank stops filling too earlyFloat set too low, a bent arm, or a float that sticksReset the level or replace the float
Banging or whistling as the tank fills or closesWorn valve, high supply pressure, or a partly closed inlet valveReplace the valve. Check the pressure. See water hammer arrestors
A slow drip from the overflowA valve that weepsClean or replace the valve
The pump keeps stopping with an alarm or cut-outThe tank level is too low to satisfy the pump's low-level protectionFind out why the tank is not filling. See booster pump
Roof tank overflows when the pump runsA transfer pump that does not stop, because its float switch or level control has failedRepair the control
Level indicator reads wronglyA stuck float, a faulty sensor or a blocked sight tubeFree, clean or replace it

Why the overflow matters

A dripping or running overflow is the tank telling you something. The overflow exists to carry the water away if the float valve fails, so if it is running, the float valve has failed. In a roof tank, the water goes down a wall or into a neighbour's balcony. In an underground tank, it can run unseen for weeks, and the only sign is a higher bill or a pump that works harder. See our leak detection page for finding water you cannot see.

Types of float valve

  • Mechanical float valves. A float on an arm or a cylinder rises with the water and closes the valve. Simple and cheap, with no electronics to fail.
  • Piston and diaphragm valves. The closing element differs, which changes how tightly and how quietly the valve shuts.
  • Level sensors with an electric valve. A sensor tells a solenoid or motorised valve when to open and close. Used on larger tanks and in buildings, and they have electronics that need testing. FAM has its own electricians for the wiring and controls.
  • Float switches for pumps. These start and stop a transfer pump rather than closing a valve.

We replace like with like where the valve suits the job. When the valve type is the cause of the fault, for example a light float valve on a high-pressure supply, we change the type. Whatever we fit is rated for the pressure it will see.

A float valve replacement

  1. Close the inlet isolation valve. If there is none, close the main supply to the tank, and we will fit one.
  2. Lower the water level below the valve, or drain if needed.
  3. Remove the old valve and check the inlet fitting and the tank wall for cracks or damage.
  4. Fit the new valve with the right washers, firmly fixed, so it cannot shift.
  5. Set the shut-off level below the overflow.
  6. Open the supply slowly and watch the tank fill and the valve close.
  7. Watch a full fill cycle. The valve should close firmly at the set level, with a clear margin below the overflow.
  8. Check for noise and drips, and tighten or adjust.

Supply pressure and float valves

A float valve closes against the pressure of the supply. Very high pressure makes it close harshly, and it can bang or leak. If the pressure is high at the tank inlet, a pressure reducing valve ahead of it protects the valve. See pressure reducing valves.

Leaking water tanks

A leaking tank wastes water and, in an underground tank, can let dirty ground water in. Finding the leak is the first job.

Is the tank really leaking?

Confirm before you repair. A float valve that overflows, a leaking outlet or a pump problem can look like a tank leak.

  1. Isolate the tank. Close the inlet and the outlet so no water enters or leaves.
  2. Mark the water level on the inside or on a sight tube.
  3. Wait. Leave it for several hours, or a day, depending on the size.
  4. Check the level. A clear drop in a covered, isolated tank means a leak, in the tank or in a fitting.
  5. Repeat at different levels. If the level stops dropping at a certain height, the leak is at that height.

The meter test from our leak detection page also helps: if the meter moves with all taps off, water is escaping somewhere on your side.

Where tanks leak

PlaceWhat it looks likeCause
Outlet, inlet or overflow connectionWet around the fitting on the outsideA worn seal, a loose fitting or a cracked bulkhead
BaseWet ground or floor under the tankA crack, a failed seam or a failed base joint
Seams and panel jointsWeeping lines or damp stainsA failed sealant or gasket in a sectional tank
WallsA crack or a wet patchImpact, ageing, stress from an uneven base, or a failed lining
Cover or hatch sealWater or dirt getting inA worn gasket, a warped cover or a loose fixing
Underground tankA rise in water use, a pump that runs more, or damp groundA crack, a joint or a pipe connection, either losing water out or letting ground water in

How a leak is repaired

The repair depends on the material and on where the damage is.

  1. Drain and dry the tank. Repairs need a dry, clean surface.
  2. Find and mark the damage.
  3. Prepare the surface. Clean, and cut back damaged material.
  4. Repair with a method suited to the material. A sectional tank may need new sealant or gaskets. A cracked panel or wall may need a laminate or a patch. A damaged fitting is replaced.
  5. Use materials suitable for drinking water. Any lining, sealant or coating that touches stored drinking water must be suitable for it. We ask the supplier to confirm this.
  6. Cure. Materials need time to harden before the tank is filled.
  7. Clean and disinfect before the tank goes back into use. See our water tank cleaning page.
  8. Test. Repeat the level test.

When to replace the tank

SituationRepair or replace
A leaking fitting, gasket or sealantRepair
A single small crack with the rest of the tank soundRepair, and keep an eye on it
A failed liningRe-line if the shell is sound
Widespread cracks, repeated leaks or a distorted shellReplace
Heavy corrosion in a metal tankReplace or treat, depending on depth
An underground tank leaking from its base, or failing under loadReplace
A tank too small or too large for the propertyReplace with the right size
A tank that cannot be cleaned because of its shape or accessReplace or modify

We do not quote a lifespan for a tank. It is set by the material, the sun and heat it sees, how well the base supports it, and how often it is cleaned.

Tanks that feed pumps

A tank problem can show up first as a pump problem.

  • A pump runs dry when the tank empties. The tank's float valve, inlet supply or outlet may be at fault. Booster sets need a low-water cut-out, because a pump that runs dry can air-lock and be badly damaged.
  • A transfer pump fills a roof tank. It needs a float switch or level control at the roof tank to stop it, and another at the ground tank to protect it from running dry.
  • Sediment at the bottom can reach the pump if the outlet is too low or the tank is overdue for cleaning.
  • Outlet position. Taking water from near the bottom, opposite the inlet, helps the tank mix, but a pump should not draw from the very floor, where sediment collects.

See our booster pump page for the pump side.

Underground tank access with a submersible pump and a hose

Villas, flats and commercial properties

Who owns the tank, and who is responsible, changes with the property.

Villas

A villa tank belongs to the property. If you own the villa, you arrange installation and repair. If you rent, read the tenancy contract: it can say who handles tanks. A cracked or failed tank is usually a repair to the property and not routine upkeep. Report it to the landlord in writing, with photos, before paying for it yourself.

Flats and buildings

Tanks in a building are shared systems run by building management or the owners' association. A shared tank is part of the building, so it falls to building management or the owners. If you notice an overflow, a leak or a fault, report it to management in writing with a photo, the time and the location.

Offices, shops and restaurants

Commercial tanks matter more, because losing water can close the business.

  • Size for the peak, not the average.
  • Consider two tanks or a split tank, so one can be cleaned or repaired while the other supplies.
  • Fit level indication and an alarm that reaches someone who can act.
  • Keep records. A food business should be able to show when its tank was last cleaned, including a shared tank. See our water tank cleaning page.
  • Plan work around opening hours.
  • A maintenance schedule can put float valves, overflows and level controls on a check list. See plumbing maintenance contracts.

Working at height and in confined spaces

Tank work carries risks that are easy to underestimate. Roof tanks mean working at height. Underground and large tanks are confined spaces, where stale air and a slippery floor make a fall or a faint hard to recover from. Entering a tank is work for trained people with a second person outside.

If you are thinking of climbing onto a roof or into a hatch to fix a float, WhatsApp us instead.

What not to do

  • Do not enter the tank.
  • Do not climb to a roof tank without a safe route and a second person.
  • Do not bend the float arm to set the level and call it fixed. A bent arm sticks.
  • Do not block the overflow to stop it dripping. That turns a drip into a flood.
  • Do not remove the screen from the vent or overflow.
  • Do not seal a leak with a general-purpose sealant that is not suitable for drinking water.
  • Do not leave a tank uncovered or with a gap at the hatch.
  • Do not fill the tank to the brim. Leave the margin between the water level and the overflow.
  • Do not ignore an overflow because the water drains away somewhere you cannot see.

How much does a water tank cost to install or repair in Dubai?

We quote the price after a survey, or from photos and the details you give us. Costs follow the work.

  • Tank size and material.
  • Number of tanks and whether they are linked by a transfer pump.
  • Access. A tank craned onto a roof or lowered into a pit costs more than one placed on level ground.
  • Groundwork. Digging, a base, drainage and backfill for an underground tank.
  • Pipework and fittings. Valves, float valves, overflow, vent, drain and level indication.
  • Pump and controls, if included.
  • Building fees. Any fees charged by the building management are separate from our price.
  • For repair: the part or the extent of the damage, and whether the tank must be drained and cleaned.

We do not publish a starting price for this job. Send a photo on WhatsApp and we give you a fixed price before we start. Prices exclude 5% VAT.

Where we install and repair water tanks in Dubai

We cover all of Dubai, including Dubai Marina, JBR, Downtown Dubai, Business Bay, Jumeirah Lakes Towers, Palm Jumeirah, Al Barsha, Jumeirah Village Circle, Dubai Hills, Mirdif, Deira and Al Quoz. See the full list of areas.

Water tank installation and repair FAQs

What size water tank do I need?

Take your daily use from a water bill, multiply by the days of cover you want, and add a margin. Treat it as a rough start: a villa with a garden or pool will use more.

Why is my water tank overflowing?

The float valve is not shutting off. The cause is a worn seal, grit in the valve, a bent arm, a float full of water, or a level set too high. Water running out of the overflow pipe tells you the valve has failed.

Why won't my water tank fill?

Check the inlet isolation valve and the strainer first. A snagged or stuck float, a worn valve or a supply problem are other possible causes.

Does a water tank need an overflow pipe?

Yes. Every storage tank needs an overflow sized larger than its inlet can supply, with a screen that keeps insects out, discharging somewhere safe and visible. We check it on every job.

How do I know if my water tank is leaking?

Isolate the tank, mark the water level, and see whether it drops over several hours. For an underground tank, a rise in water use or damp ground nearby are warning signs.

Can a leaking tank be repaired?

A leaking fitting, gasket or sealant can be a repair. Widespread cracks or a distorted tank point to replacement. Any repair material that touches drinking water must be suitable for it.

Does my tank need a cover?

Yes. A drinking-water tank should be covered and built to prevent contamination, including its overflow tank.

How long does a tank installation take?

A float valve replacement is a short job. A new tank takes longer, and underground tanks and tanks lifted onto roofs take longer still. We give you the expected time when we quote.

Do I need approval to install a tank in a flat?

Tanks in a building are shared, so check with building management first. Ask whether written approval is required before work starts.

Do you offer a guarantee?

Yes. We give a 30-day workmanship warranty on our labour. Parts carry the manufacturer's warranty only.

How much does it cost?

We do not publish a starting price for this job. Send a photo on WhatsApp and we give you a fixed price before we start. Prices exclude 5% VAT.

Book a water tank installation or repair in Dubai

Tell us what you have, what it is doing, and where the tank sits. A photo of the tank, the float valve and the overflow helps. We will send a plumber to survey it and quote.

WhatsApp: +971 55 407 7427 · Request a quote

Visit us: Office 871, Oasis Mall, Al Quoz 1, Dubai, UAE

Related services: Water tank cleaning · Booster pump installation and repair · Low water pressure fix · Pressure reducing valves · Leak detection · Emergency plumber