Skip to content
FAM Plumbing

CPVC Pipe in Dubai: Sizes, Ratings, Chemicals, Prices

CPVC pipe is sold under one name for three different jobs: hot and cold water in a home, heavy industrial pipe in Schedule 40 and 80 walls, and thin-walled fire sprinkler pipe. The comparison with PPR, copper and PEX is on our(/services/pipes/repiping) page and the cement steps are on the(/services/pipes/pipe-fittings) page, so this page does not repeat them.

  • Workmanship guarantee
  • Open 24/7
Green PPR pipes on a wall with a hand test pump connected

CPVC pipe in Dubai: what we do

  • Identifying the pipe you have, by outside diameter, wall and marking, so a repair uses the right fitting and cement. See pipework for the other materials.
  • Repairing a cracked or leaking CPVC section, by cutting out the damaged length and joining new pipe with a coupling. See pipe leak repair.
  • New hot and cold water lines in CPVC for a fit-out or an extension, tested under water pressure.
  • Finding the product that damaged the pipe, when a crack appears at a firestop, a sealant, a thread or an insulation wrap.
  • Joining CPVC to PPR, copper and metal threads, through the right adapter. See pipe fittings.
  • Supports, expansion and insulation on hot lines. See pipe insulation.
  • Water heater connections, where a hot line meets a tank. See water heater installation.
  • Emergency visits. We answer calls and send a plumber 24 hours a day, 7 days a week, including nights, weekends and public holidays.
  • Areas. Across Dubai. The list is near the end of this page, and the full list of areas is on its own page.

What the name covers

A quotation that gives only the material leaves the size system, the wall and the pressure open. These are the names you will meet:

NameWhat it means
CPVCChlorinated polyvinyl chloride: PVC with extra chlorine added. The chlorine raises its temperature rating and its fire resistance
SDR 11, SDR 13.5, Sch 40, Sch 80Wall-thickness systems, explained below
CTS and IPSCopper tube size and iron pipe size, the two outside-diameter systems, explained below

The next thing to ask is which of the three families the pipe belongs to, and the marking printed on the pipe answers that.

CPVC against PVC

CPVC and PVC look alike and are not interchangeable. Temperature is the difference that decides the job.

PointCPVC against PVC
Temperature limitPVC tops out at about 60°C. CPVC is rated for continuous service up to about 93°C, at a much lower pressure
ColourPVC is white or dark grey. CPVC is off-white, light grey or yellow, depending on the family
CementNot interchangeable. PVC and CPVC each need their own cement
PricePVC costs less per metre and for fittings

The pressure section below shows what the rating has fallen to by the time the water is hot. Read the temperature against the pressure on the data sheet of the pipe you are buying, and never judge the pipe by the temperature alone.

CTS, IPS, SDR and Schedule: which CPVC pipe is which

CPVC is made in three families, and the marking printed on the pipe tells you which.

FamilyOutside diameter systemWall systemUse
Hot and cold water tubeCTS, the outside diameters of copper tubeSDR 11Hot and cold water distribution in homes and buildings
Industrial pipeIPS, the outside diameters of iron pipeSchedule 40 or Schedule 80Water treatment, hot chemical drainage and process lines
Fire sprinkler pipeIPS-based nominal sizesSDR 13.5Wet-pipe sprinkler systems. Not ours: FAM does not do fire-system work

The wall systems work differently. SDR is the outside diameter divided by the wall thickness, so the wall grows with the pipe and the rating stays the same. A schedule works the other way: the larger the schedule number, the thicker the wall, and the pressure rating falls as the pipe gets larger.

One practical point when reading a marking: ¾ in CTS tube (22.2 mm) and ½ in IPS pipe (21.3 mm) are under a millimetre apart, close enough to be taken for each other in a box. The marking and a caliper settle it.

Sizes: what the printed diameters are

Both systems are named in inches that are not the pipe's outside diameter, and a metric label such as 20 mm or 25 mm is a third naming habit.

Nominal sizeCTS outside diameterIPS outside diameter
½ in15.9 mm21.3 mm
¾ in22.2 mm26.7 mm
1 in28.6 mm33.4 mm
1¼ in34.9 mm42.2 mm
1½ in41.3 mm48.3 mm
2 in54.0 mm60.3 mm

The table gives no inside diameter, because it changes with the wall and the family. The maker's data sheet gives the true figure.

A pipe sold as "20 mm" has no CTS or IPS size at 20 mm: the nearest are CTS ¾ in at 22.2 mm and IPS ½ in at 21.3 mm. A pipe sold as "25 mm" sits between CTS ¾ in and CTS 1 in, and close to IPS ¾ in at 26.7 mm. So the label is a name and not a measurement. Measure the outside diameter of the pipe with a caliper, or of the pipe you must join to, and match it to the fitting's socket before you buy.

Pressure falls as the water gets hotter

A CPVC rating is a pair of numbers, a pressure and a temperature, and a pipe rated at its full pressure holds it only at room temperature. For the SDR 11 hot and cold water tube the typical ratings are about 27.6 bar at 23°C and 6.9 bar at 82°C. Between them the rating falls as the water heats.

Water temperatureTypical rating, SDR 11 tube
23°C27.6 bar
38°C22.6 bar
49°C17.9 bar
60°C13.8 bar
71°C11.0 bar
82°C6.9 bar

These are typical figures and the maker's data sheet for the pipe in the box governs. The figure that matters is the rating at the hottest the line gets, not the one at room temperature. The pressure the line sees is the supply pressure plus any rise when a heater heats a closed system. The water heater pages cover the heater side.

Chemicals and products that crack CPVC

CPVC does not usually fail by itself. A crack is the end of a process that began earlier, and it needs three things together: a flaw or stress in the pipe, such as an over-tightened thread or a joint under strain; a chemical that attacks the plastic; and time. Take away any one and the pipe survives. The chemical is the one we can control on site.

Products that commonly attack CPVC include:

  • Some firestop sealants and caulks, especially those containing certain surfactants or solvents.
  • Thread sealants and pastes that are not made for CPVC. PTFE tape is the safe choice on threads.
  • Cutting oils and some lubricants left on the pipe after threading a metal fitting nearby.
  • Soapy leak-test liquids and some cleaners, including strong household cleaners and ones containing ammonia or citrus oils.
  • Solvent-based paints and adhesives, and petroleum-based products generally.
  • Some pipe insulation and flexible vinyl, where plasticisers can migrate into the pipe. Polyethylene and fibreglass insulation are the usual safe choices.
  • Pest-control and anti-corrosion sprays used in a shaft or ceiling void.

The cheapest check is the label. Before a firestop, a sealant, a tape, a lubricant or an insulation goes near a CPVC line, find the product's maker and the pipe's maker, and look for the product on the pipe maker's compatibility list. A product on neither list is a product to leave off.

Even a small exposure can damage the pipe in a way that shows months later, so a cracked pipe does not tell you which product did it. When we find a crack, we look at what was used near it before we decide on the repair.

Cutting and solvent welding: what differs from the pipe-fittings page

The pipe fittings page gives the six-step cement sequence. These points are specific to CPVC:

  • Cutting. Use a wheel cutter, a ratchet cutter or a fine-tooth saw in a mitre box. Avoid scissor-style cutters, which crush the wall, and remove the raised ridge a wheel cutter leaves. Pipe that has been damaged should be cut at least 50 mm beyond the damage.
  • Deburring and bevel. Remove burrs from the inside and outside, and put a slight bevel on the end of the pipe so it enters the socket without scraping the cement off.
  • Cement and primer. Use the cement and primer made for CPVC and for the pipe family, applied in the order the maker states. Never use PVC cement.
  • Hold times. Hold the joint for the time the cement maker states, to stop the pipe pushing out of the socket.
  • Test medium. Pressure test with water after the joints have cured, never with air.
  • Gas. CPVC is not for gas. See gas pipe for pipe that is made for gas.
Plumber carrying a toolbox beside rows of copper pipes

Cure times, heat and humidity

Cure time depends on the pipe size, the temperature and the test pressure. A small joint on a warm day waits minutes to an hour before a low-pressure test. A large joint waits hours, and a higher test pressure lengthens every wait. The cement maker's data sheet gives the figure for the size and the pressure, and a pipe lying in the Dubai sun can be well above the temperatures such tables cover, so we follow the data sheet for a hot site.

Heat shortens the working time at the joint. On a 35°C day, a pipe lying in the sun can be at 45 to 51°C, and the solvent attacks a hot surface faster and deeper. What we do:

  • Store cement and primer in shade.
  • Shade the pipe and fittings, or at least the ends to be joined, and cool the surfaces with a damp rag, then let them dry before cementing.
  • Weld in the cooler hours, and make anchored and final connections then.
  • Use primer and a heavier, high-viscosity cement for more working time, and shake or stir the cement before use.
  • Keep the socket free of puddles and wipe the excess off the outside of the joint.
  • Use more hands on larger pipe, so both surfaces are still wet when they meet.
  • Allow for more expansion and contraction, which hot weather increases.

Humidity works the other way. Humid air slows the cure, and in very humid weather allow up to half as long again before testing.

Supports and expansion

Support spacing for CPVC closes up as the pipe gets hotter, and the pipe grows as it heats. A small pipe is supported about every 1.5 m when cool and closer, about every 1.2 m, at 60°C. A larger pipe or a thicker wall spans further. The pipe's maker gives the spacing table for the pipe you are buying, and we work to it.

Growth is the second reason for the spacing. CPVC expands about 0.06 mm per metre for every °C of rise, and the growth does not depend on the pipe diameter. A hot run of 12 m that goes from 20°C to 60°C is a rise of 40°C and grows about 29 mm.

  • Do not clamp the pipe against its own movement. Hangers must leave the pipe free to slide, and a rigid point support is not for thermoplastic pipe.
  • Let a long run bend. Long straight runs or big temperature swings need expansion loops or offsets, and direction changes, especially 90 degree elbows, give flexibility. Hangers must not lock those changes.
  • Support valves separately, and add support near valves and at the change to a metal pipe.
  • Relief valve drains. See water heater installation for the heater side.

Fire sprinkler CPVC

Sprinkler CPVC is a different pipe from the water tube, with its own wall, fittings and cement. A sprinkler system is part of the building's fire protection, and FAM does not do fire-system work. We do not alter a sprinkler line, and we do not cement hot and cold water tube into one. Changes to it go through the building's fire-protection contractor.

If you have a CPVC pipe and you are not sure whether it is sprinkler pipe or water pipe, the marking tells you. Send us a close photograph on WhatsApp and we will read it.

Sun, roofs and outdoor runs

CPVC is made for indoor use. Ultraviolet light breaks the plastic down, and a line in direct sun grows brittle over a few seasons. The repiping page covers the indoor-only rule.

Outdoors in Dubai, the sun is also a heat problem in the rating. Water that has warmed in a roof pipe or a tank line can reach 40°C or more in summer, and the rating of the SDR 11 tube at that temperature is nearer 20 bar than 27 bar. A cold line on a roof or in a shaft in the sun is a warm line for the purpose of the rating, so use the pressure table above for it. Where a CPVC line has to cross an exposed area, we prefer to move it into a duct or box, or to use a metal pipe for that stretch, and not to rely on paint or wrapping.

Recognising CPVC in a Dubai home

CPVC hot and cold water tube is cream, off-white or pale yellow, and it is printed along its length with the maker, the size and the family. It was common in villas and some low-rise buildings for both hot and cold lines, and the same pipe is often found in a roof void or a shaft. It looks like PVC but is lighter in colour than grey PVC drainage pipe, and it has a smaller diameter than the pipes used for waste. PPR is a different pipe again, usually green or grey, fused with heat and not cemented. If the pipe has no marking, send us a close photograph and a coin for scale and we will say what it is before anyone cuts it.

A cracked CPVC line: what we do

A crack in a CPVC line usually runs along the pipe, or sits at a fitting, a thread or a clamp. We shut the supply, drain the section and look at the crack and at what is near it, because a product on the pipe is often the cause. We cut the pipe back at least 50 mm beyond the damage, until the pipe is sound, and join a new length with couplings or a union, cemented with the right cement and primer. A single crack with a clear cause is a repair. Where the pipe cracks again nearby, or breaks easily when cut, it has gone brittle and the whole run is the problem. We test with water after the cure time and write the product list on the note.

Threaded joints and connections to a water heater

A CPVC line that meets a metal thread, a valve or a water heater is joined with a transition fitting made for the pair, and the thread is sealed with PTFE tape and not paste. The plastic side is the weak side, so the thread is tightened by hand and a small turn and no more, because an over-tightened thread is the commonest starting point of a crack. A hot tank connection should be made with a union or a flexible connector, so heat from the tank does not travel along a rigid metal nipple and soften the plastic. See water heater installation.

When a CPVC system is past repair

A CPVC system that has been in the sun, near hot ceilings or near strong chemicals for years can become brittle. The signs are pipe that snaps instead of bending when it is cut, hairline cracks at several joints, and leaks that move from one fitting to the next after each repair. In that case, patching costs more over time than replacing the run. We put the repair price against the cost of replacing the line and give you both in writing. A replacement is usually PPR for hot and cold water, which is fused and handles heat well. See repiping and PPR pipe.

Why CPVC fails at a fitting and not along the pipe

The wall of a fitting is thicker than the pipe, and the plastic around a socket or a thread carries the stress of the joint. A fitting under strain from a misaligned pipe, a rigid hanger or a thread that was forced is stressed all the time, and a chemical on the surface finds the weak point. That is why most cracks sit at fittings, and why checking the alignment and the supports matters as much as the cement. When we replace a fitting we check the pipe either side is free to move and is not pulling on the joint.

Plumber fitting pipe on a manifold of red and blue pipes

What to send us for a CPVC problem

A few photographs save a wasted visit. Send a close photograph of the pipe with its printed marking, one of the crack or leak, and one wider shot that shows what is around it: a firestop collar at a slab, a sealant bead, a lagging wrap, a metal thread or a heater. Tell us whether the line carries hot or cold water, how old the pipe is if you know, and whether anyone has worked near it recently, such as a pest-control visit, a painter or an air-conditioning technician. A crack that appears a few months after nearby work is a strong clue to the product that caused it, and we note it on the report so the same product is kept off the new pipe.

CPVC in ceiling voids and hot shafts

A CPVC line in a ceiling void or a shaft can sit for years in warm, still air, which is hotter than the room below. The heat lowers the pressure rating and speeds up the ageing of the plastic. Where we open such a void for another job, we look at the pipe, press a clean section gently and check the supports and the joints. Pipe that is discoloured, chalky or marked by drips from above is flagged on the report, and a hot line that runs close to a light fitting or a hot duct is moved or lagged.

Eight checks before you buy or accept a quote

  1. The family, and the marking stamped on the pipe. Hot and cold water tube, industrial pipe and sprinkler pipe are different products, and the marking says which one you hold.
  2. The outside diameter in millimetres, and the fitting that matches it. Measure the pipe or the socket. A "20 mm" label is a name and not a measurement.
  3. The rating at the hottest the line gets. Ask for the pressure at 60°C and at 82°C, and compare it with the supply pressure and the heater's set point. A temperature without a pressure is not a rating. Take the maker's figure for the pipe in the box.
  4. The family's use. Water tube for hot and cold water. Never sprinkler or industrial pipe in a water line.
  5. The cement and primer. CPVC cement and primer, in the colour for the family. Never PVC cement. The cure time is the cement maker's, at the temperature on the day.
  6. The products near the pipe. Firestop, sealant, tape, insulation, lubricant and cleaner, each checked against the pipe maker's list before it is used.
  7. The supports and the expansion. The spacing at the line's temperature, a loop or an offset on a long run, and hangers that do not squeeze the pipe.
  8. The test. A water pressure test after the cure time, with the pressure, the duration and the date written down.

Permission in Dubai: who decides on CPVC pipework

CPVC runs inside walls, ceilings and shafts that belong to the building, and in a rented home they also touch the landlord. The fuller account is on the repiping page.

  • Building management. A riser or shaft shared with other units is the building's, so work that reaches it, or that needs the water shut off for other units, goes through building management.
  • Fire protection. A sprinkler pipe is part of a fire system, and not our work.

Replacing a cracked length of CPVC in your own unit with the same pipe is maintenance, and needs a message to the landlord. Re-routing a line, changing the material or opening a wall or ceiling is an alteration, and needs written consent in a rented home and the building's approval. Tell us what your building asks for and we work to it.

When the job is finished

Ask for these. They cost nothing to produce.

  • A drawing as built, with the route of the new pipe, the valves and the supports marked.
  • Photographs before the wall or ceiling is closed: the pipe's marking, the joints, the supports and any firestop at a slab.
  • The pipe and fittings, by name, with the family, the size and the brand.
  • The cement and primer used, by name, with the date.
  • The cure time allowed before the test, and the temperature on the day.
  • A water pressure test, with the pressure, the duration and the date. No air or gas test.
  • The products used near the pipe: the sealant, the tape, the insulation and the firestop, each by name.
  • The supports and the expansion allowance, with the spacing used.
  • FAM's workmanship warranty, in writing. The warranty runs for 30 days and covers our labour only. Parts carry the manufacturer's warranty only.

How we work

  1. You tell us what you see and where, with photographs of the pipe, any marking and any crack on WhatsApp.
  2. We identify the pipe by its outside diameter, its marking and what it joins.
  3. We check the sealants, firestops, tapes and insulation near it against the pipe maker's compatibility list.
  4. We give a price and a method in writing, with the pipe, the cement and the cure time named.
  5. Check permission. In a rented or managed property, ask the landlord or building management whether they need to approve this work before the visit.
  6. We work in the cooler hours where the job is exposed, and keep cement and pipe in the shade.
  7. We test with water, wait the cure time, and hand over the photographs, the product list and the test record.

Where we work in Dubai

We cover all of Dubai, including Dubai Marina, JBR, Downtown Dubai, Business Bay, Jumeirah Lakes Towers, Palm Jumeirah, Al Barsha, Jumeirah Village Circle, Dubai Hills, Mirdif, Deira and Al Quoz. See the full list of areas.

How much does CPVC pipework cost in Dubai?

  • The work. Cutting, cementing, supporting, testing and making good.
  • What moves the price. The family and size, the length, the number of fittings, access, exposed or concealed routing, insulation, pressure testing, and the building's approval.

We do not publish a starting price for this job. Send a photo on WhatsApp and we give you a fixed price before we start. Prices exclude 5% VAT.

CPVC pipe FAQs

What is the difference between CPVC and PVC?

The cements are not interchangeable: PVC and CPVC each take their own. PVC also costs less. CPVC is the one rated for hot water. The comparison with PPR and copper is on the repiping page.

How hot can the water in CPVC pipe be?

Most CPVC is rated for continuous service up to about 93°C. The pressure falls with the heat: the SDR 11 tube is rated about 27.6 bar at 23°C and 6.9 bar at 82°C. Use the maker's figure for the pipe in the box, and see the pressure table on this page.

What do CTS, IPS, SDR 11 and Schedule 80 mean?

CTS means the pipe has the outside diameters of copper tube, and the hot and cold water tube is made that way, in SDR 11, which has a wall of one eleventh of the outside diameter. IPS means iron pipe size, and Schedule 40 and 80 are its walls, with 80 the thicker. The sprinkler pipe is SDR 13.5. The sizes table on this page prints the outside diameters in inches and millimetres.

Can I use PVC cement on CPVC?

No. PVC cement is not made for CPVC, and the joint can fail. CPVC takes its own cement. The six cement steps are on the pipe fittings page.

Can CPVC go on a roof or outdoors in Dubai?

Not for long. Sunlight breaks CPVC down, so keep it indoors or in a duct, and use metal pipe for exposed stretches. Water in a roof pipe also gets hot, which lowers the pressure the pipe can hold.

What damages CPVC pipe?

A mix of a flaw or stress in the pipe, an incompatible chemical and time. Common culprits are firestop sealants, thread pastes, cleaners, some insulation and solvent-based paints. Check each product against the pipe maker's list before it touches the line.

How long do I wait before testing the pipe?

It depends on the size, the temperature and the test pressure. A small joint can wait a short time before a low-pressure test, and a large joint several hours. Humid air slows curing, so allow longer in a Dubai summer. Test with water, never air.

Can CPVC be joined to PPR, copper or a tap?

Yes, through an adapter made for the pair and not by cementing or fusing one onto the other. The pipe fittings page covers PPR to CPVC and to metal threads.

Can CPVC carry gas or compressed air?

No. For pipe made for gas, see the gas pipe page.

How much does CPVC pipe cost in Dubai?

The pipe is a small part of the bill. The price depends on the diameter, the length of the run and how much has to be opened up to reach it. We give a fixed price on WhatsApp after a visit or from photos. Prices exclude 5% VAT.

Book a CPVC pipe visit in Dubai

Tell us what the pipe does (hot water, cold water, sprinkler or a process line), where it is cracked or leaking, any marking printed on it, and whether you rent or own. A photograph of the pipe, close up, with a coin or a ruler beside it, helps us tell the size. If water is escaping, shut the supply and call.

WhatsApp: +971 55 407 7427 · Request a quote

Visit us: Office 871, Oasis Mall, Al Quoz 1, Dubai, UAE

Related services: Repiping · Pipe fittings · Pipework · PPR pipe · Pipe insulation · Pipe leak repair · Water heater installation · Gas pipe