Urinal installation and repair in Dubai: what we do
- Installing wall-hung, stall, floor-standing and trough urinals, including the support, waste and supply.
- Fitting and replacing flush valves, concealed cisterns and sensor units.
- Waterless urinals: fitting, cartridge and sealing-liquid changes, and checks on the drain below.
- Fixing leaks at the urinal's waste connection, supply and wall.
- Clearing a slow or blocked urinal and its trap.
- Diagnosing smell, whether it comes from the bowl, the trap, the drain or the walls and floor nearby.
- Squat toilet (Arabic pan) installation and repair, with its trap, flush and floor.
- Replacing a worn sensor battery pack and re-aiming a sensor that does not see the user.
- A written note of what was fitted, the settings and the test result.
- Emergency visits. We answer calls and send a plumber 24 hours a day, 7 days a week, and we do not promise an arrival time.
Neighbouring topics have their own pages. Western-style toilets, seats and smart toilets are on toilet installation, the cistern and flush on toilet repair and cistern repair, and a toilet that will not clear on toilet unblocking. Backflow protection on a flush valve is on backflow prevention. Drains beyond the fixture are on drain unblocking, valves on valve repair and replacement, supply pressure on pressure reducing valves and low water pressure, and the descaling of fittings on water softener.
Urinal types: what each one is
The type decides the supply, the wall and the upkeep.
| Type | What to know |
|---|---|
| Wall-hung bowl | A bowl on brackets, with the waste and supply in the wall. The most common type in offices and shops. Easy to clean under |
| Stall | A floor-reaching unit, often with side partitions for privacy. Common in hotels, airports and busy sites. Easier for wheelchair users to approach |
| Trough | A long channel shared by several users. Seen in older and heavy-use sites, with a single flush for the whole trough |
| Rimless | An open design with no inner rim, so water spreads evenly and there are fewer places for build-up |
| Waterless | No flush. A trap with a sealing liquid or a membrane blocks smell, and a cartridge is replaced on a schedule |
The flush system is a second choice, separate from the type. A mains-supplied urinal flushes from the mains on a button or sensor, needs no cistern, and is easier and cheaper to fit. A cistern-fed one flushes from a tank above or behind the wall, and suits sites where the mains pressure is weak. Waterless urinals need regular cleaning and cartridge changes, and sensor and timed models are common for hygiene.
Rough-in, height and spacing
Rough-in is the position of the waste and supply in the wall before the fixture goes on. The maker's drawing for the model in the box gives the exact dimensions, and we follow it. The points below are what we check before the pipework is closed in.
| Point | What to check |
|---|---|
| Rim height | Set for adult users, and lower for children's washrooms. The drawing or the fit-out design gives the height |
| Wall space | Enough clear wall on each side of the fixture, centred on the bowl |
| Spacing between units | Enough room between centres that users do not crowd each other. Privacy screens change what is needed |
| Accessible urinal | A floor-reaching bowl is preferred where one is provided for disabled users, with its lip low enough to approach and grab bars on both sides |
| Waste | The waste pipe and its coupling must suit the fixture's outlet, without standing far past the finished wall |
| Water | The supply is trimmed to stand only a short way out of the finished wall |
| Support in the wall | A solid support behind the bracket position, wide enough to take the fixings |
Three notes. First, accessible fit-out rules apply to public and common parts and not to individual dwellings, so they do not set dimensions for a urinal in a private home. Second, we fit to the urinal maker's rough-in drawing for the model in the box, and check it against the building's design drawings where a fit-out has them. Third, where a unit is provided for disabled users, we ask the designer for the accessible lip height and bar positions before we drill.
Fitting: the order of work
The maker's installation sheet gives the order for the model in the box, and we follow it. The usual sequence:
- Check that the rough-in matches the drawing, the waste coupling does not stand proud of the wall, and the wall area is clean.
- Mark the bracket position from the finished floor, drill and fit the brackets.
- Test-fit the urinal to confirm that the waste, water and brackets line up.
- Make the water connection with the seal lubricated and seated.
- Make the waste connection, trimming the trap outlet to length and checking the coupling suits the waste pipe.
- Fix the urinal to the wall with the supplied fixings.
- Run water into the urinal, confirm it drains freely with no leaks, and then seal around it with sanitary-grade silicone.
Care instructions are to use a soft, non-abrasive cloth with mild detergent, and not to use scouring creams, strong drain cleaners, special metal cleaners or bleach. A different model changes the trap and the heights, so we follow the maker's sheet for the model in the box.
Supply and flush: valves, cisterns and sensors
A flushing urinal needs a measured burst of water that washes the bowl and refills the trap, and the flushing device is the part that wears.
| Flush device | What to know |
|---|---|
| Mains flush valve (manual or sensor) | A valve on the mains-pressure supply that delivers a fixed volume each flush. It is not supplied with the urinal and must suit the pressure and the volume wanted |
| Cistern-fed | An automatic cistern that fills slowly and flushes at set intervals, or a cistern flushed by hand. A slow-fill cistern flushes whether or not anyone has used the urinal |
| Sensor | An infrared sensor detects the user and triggers a solenoid or valve after use. It avoids manual contact and keeps the flush volume consistent |
| Timed flush | Flushes at set intervals. It can waste water in quieter hours |
A urinal should be supplied from a flushing device that delivers enough water for an effective wash and for refilling the trap, and no more. A time-switch isolating valve on a cistern supply, or a sensor, stops a cistern flushing when the building is empty.
Backflow protection on a supply is covered on backflow prevention and is not repeated here.
Pressure and the flush valve
A flush valve is rated for a range of pressure. A pressure above its rating is a pressure reducing valve question and a weak supply is on low water pressure. We measure the pressure at the valve while it is flushing, and read the valve's rated range from its data sheet, before we diagnose a short flush as a worn part.
Flush volume and water use
No single figure describes what a urinal uses. A standard flushing urinal uses a modest amount per flush, a water-saving model uses less, and a waterless urinal uses none.
The volume is set by the flush valve or the cistern, and the sensor or timer sets how often it runs. We do not claim a saving for a particular model or for a Dubai site. Where a building's fit-out brief specifies the fixtures and the flush volume, we fit what it states.
Waterless urinals
The claims made for waterless urinals are strong, and the maintenance is what decides whether they work.
- How they work. A trap with a sealing liquid, or a one-way membrane, sits below the bowl. Urine passes through, and the seal blocks smell.
- The cartridge. It is replaced on the maker's schedule, commonly every few months or after a set number of uses. In a busy washroom the use count runs out before the calendar does, and in a quiet one the calendar does. We write the date and the use rate on the note.
- Failure signs. A smell, slow draining or a leak below the unit. Wear gloves and eye protection and avoid contact with waste water.
- Smell. A waterless urinal that is not maintained smells. Both trap types, a blocking fluid or a membrane, need regular upkeep, and if it is neglected the washroom smells. In some sites the answer has been to go back to a flushing urinal.
- Cost and effort. Upkeep is regular and labour-intensive, the upfront cost can be higher, retrofitting can be complex, and staff need to know what to clean and what not to.
The care rules are consistent across the makers. Water should not be used to clean a waterless urinal, because it can flush out the sealing liquid. Clean the inside and outside with an all-purpose cleaner. Do not flush the cartridge with water after adding sealant. Mineral deposits from urine can build up in the short drain below the cartridge and slow the flow.
We make no savings claim for a waterless urinal on a Dubai site, because the saving depends on how many people use it and how well it is kept.
Faults and odour: where they come from
| Fault | What to know |
|---|---|
| Runs on after the flush (continuous running) | Debris blocking the diaphragm bypass or lodged under the diaphragm, low line pressure, a damaged diaphragm assembly, or a solenoid stuck open |
| No flush | A damaged override button, flat batteries, a faulty sensor module, a solenoid stuck closed, or a scratched sensor window when the override works and the sensor does not |
| Weak or short flush | Low pressure, a diaphragm of the wrong rating, a perforated diaphragm causing short flushes, or a loose locking ring. Random flush length points to pressure fluctuation |
| Scale and deposits | A waste pipe can block with a build-up of mineral deposits from urine, which can also narrow the short drain on a waterless unit |
| Leak at the wall or trap | A water or waste seal that is not seated or lubricated, a waste coupling ring that does not suit the pipe, or a trap outlet trimmed too short. We check in the reverse of the fitting order |
| Smell from the drain with no fault in the bowl | A trap that has dried out or a blocked drain below the fixture. A drain beyond the fixture is on drain unblocking |
One point from this table needs care. Looking at splashing and at the cleaning method first costs nothing and is the cheaper first check. Look at the user side first (walls, floor, bowl and cleaning method), then the trap and cartridge, then the drain below, and only then the supply and flush valve.
If water is coming through a wall or ceiling and the urinal is not obviously the source, see pipe leak repair and ceiling and wall leak.

Accessibility and privacy
Public and common-area washrooms are usually required to provide for disabled users, and the building's fit-out designer sets the details. The common points:
- Provision: an accessible urinal where the design calls for one.
- Form: a urinal that reaches the floor is preferred, with the bottom lip low enough to approach.
- Grab bars: vertical bars on both sides at the heights on the drawing.
- Privacy screens: where provided, with clear room for a user.
- Floor: a non-slip surface in the washroom.
These rules apply to public and common parts, not to individual dwellings. Where a washroom is a fit-out for a tenant, the accessible urinal and its bars are set out by the fit-out designer, and we install to those drawings. Wall reinforcement behind a grab bar is a building question, so we ask for the drawing before we drill.
Squat toilets (Arabic pans)
A squatting pan is a fixture set into the floor, and it is the other fixture on this page's service heading.
A pan set into the floor needs depth below the floor level for its trap seal, and the amount depends on the pan. Above the ground floor, that can mean a lowered ceiling below or a raised platform. The figure depends on the pan, so it is a prompt to measure and not a design figure. A pan set into the floor needs depth that a slab may not provide, so on any floor above ground we look at the slab thickness, the ceiling below and the pipe route before quoting, and we ask the building whether the work needs sign-off. A squat pan raised on a platform is a different job from one sunk into the floor, with different access and cost. Our own team does the civil work and the finish.
For the cistern and flush see toilet repair, and for a blocked pan see toilet unblocking.
Permission in Dubai: who decides on a urinal
Replacing a failed flush valve, sensor or cartridge is maintenance. Fitting a urinal where there was none changes the waste and supply, so it is an alteration. This is general information, not legal advice. The fuller account is on our shower installation and water heater installation pages. Where a urinal job falls:
| Job | Starting point |
|---|---|
| Replacing a flush valve, diaphragm, sensor or battery pack | Maintenance, and the landlord's by default, unless your contract says otherwise. Tell the landlord first and get the decision in writing |
| Changing a waterless cartridge | Routine upkeep. Check your contract for who maintains fittings |
| Replacing a urinal like for like | A fixture swap on the existing waste and supply. Ask the landlord, and the building manager where a shared riser is touched |
| Adding a urinal, or moving the waste or supply | An alteration. Written landlord consent, and building management |
| Converting a flushing urinal to waterless | Changes the fixture and the drain's duty. Written consent, and a drain check first |
| Fitting a squat pan into the floor | Floor and waste work, possibly slab and ceiling below. Written consent and building management |
We cannot say whether your building needs a certificate for a particular job. Building management can, and a request in writing is cheaper than a stopped job. Tell us what your building asks for and we work to it.
Warranty and the handover
What you should have when the job is finished:
- A written note of the urinal make and model, the flush valve or cistern, the flush volume setting where the valve has one, and where the isolation valve is.
- The test result: the leak check at the supply and waste, the flush test, the drain check, with the date.
- The cartridge date, for a waterless urinal, with the use rate we assumed, and the cartridge model so the right one is bought.
- The maker's sheet and warranty terms. A fixture's warranty is the maker's or seller's, not ours. Read what it excludes.
- FAM's workmanship warranty, in writing. The warranty runs for 30 days and covers our labour only. Parts carry the manufacturer's warranty only.
How we work
- You send us photos on WhatsApp: the urinal, the label or model number, the valve or cistern, the wall behind it and the room.
- We check the rough-in and the supply on the visit: the waste position, the supply, the pressure at the valve and the trap. The visit fee is AED 50 + VAT, credited if the work goes ahead.
- We give options and a price in writing, including the fixture, flush device, cartridge or sensor, the wall work and the drain check.
- Check permission. In a rented or managed property, ask the landlord or building management whether they need to approve this work before the visit.
- We isolate the supply and fit or repair the parts, to the maker's rough-in sheet for the model.
- We test: the flush at the valve's rating, the sensor at the user's position, the trap refill, every joint dry and the drain.
- We hand over the written note, with the cartridge date, battery date and test result.
Where we work in Dubai
We cover all of Dubai, including Dubai Marina, JBR, Downtown Dubai, Business Bay, Jumeirah Lakes Towers, Palm Jumeirah, Al Barsha, Jumeirah Village Circle, Dubai Hills, Mirdif, Deira and Al Quoz. See the full list of areas.
Choosing a urinal for the building
Urinals are used in offices, malls, mosques, schools and restaurants. The choice depends on the traffic and the cleaning routine.
| Type | Suits | Notes |
|---|---|---|
| Wall-hung bowl with a flush valve | Offices, shops | Easy to clean, needs a flush supply |
| Trough | Stadiums, schools | Cheap, hard to keep clean |
| Stall | Heavy traffic | Strong, easy to clean, larger floor use |
| Waterless | Sites where water is costly or hard to supply | Needs the correct cartridge and regular care |
| Sensor flush | Premises with hygiene concerns | Needs power or batteries, and good cleaning |
Mounting a urinal on different walls
The wall decides what the fixings can hold, and a urinal full of water is heavier than it looks.
| Wall | What to do |
|---|---|
| Solid concrete or block | Fix to the wall with suitable anchors after checking the drawing for pipes and cables behind |
| Hollow block or a cavity | Use a fixing made for hollow walls, or put a support behind the bracket position |
| Plasterboard or a partition | Add a solid support behind the bracket position before the board goes on. A bracket fixed into board alone pulls out |
| A wall that holds a pipe riser | Ask building management, because opening or drilling a shared riser wall is not ours to decide |
| A wall with tiles | Choose the fixing positions before tiling where we can, so the bracket holes are not drilled through finished tile |
If the wall is not sound, we say so and quote the reinforcement, and our own team does the civil work and the finish.

Why a urinal smells
Most urinal smells are a failure of the trap, the flush or the cleaning. The usual causes are:
- A dry trap. If water evaporates or siphons away, sewer gas rises.
- Scale and uric salts. Deposits build up in the pipe and the outlet, hold odour and narrow the way.
- A weak or irregular flush. The pipe is not washed.
- A poor vent. Air cannot move and the water in the trap is pulled away.
- A blocked strainer or outlet. Waste lingers.
- Cleaning that does not reach the outlet. The bowl is wiped, and the pipe is left.
A plumber checks the flush, the trap, the vent and the pipe in turn.
Care between service visits
For a busy urinal, a routine helps:
- Clean the bowl and the strainer daily with a suitable cleaner.
- Pour water into any seldom-used trap to keep the seal.
- Check the flush works every day. A sensor with a flat battery is a common fault.
- Descale the outlet and the pipe at regular intervals, according to the hardness of the water.
- Replace cartridges in waterless units as the maker advises.
- Keep a note of the faults.
Water saving without a smell
Reducing the flush volume saves water, but a flush that is too small does not clear the pipe. A good approach is to set the flush to the volume the maker advises, check the bowl clears, and make sure the pipe is not too long or too flat. A timer or sensor stops flushes when the building is empty. Waterless urinals avoid the flush but need correct installation and care of the trap.
What a visit for a urinal covers
We look at the bowl, the fixings, the flush valve or cistern, the pipe and the waste. We test the flush and the drain, check the seals and the fixings, and tell you what is wrong. For a new urinal, we confirm the heights and spacing with you, fit the bowl firmly, connect the supply and waste, and test. Prices exclude 5% VAT, and the price is fixed on WhatsApp before work starts.
Training users, and signage
A urinal block needs the users to help. A small sign asking people to stay close, a clear note on how a sensor works, and a reminder not to drop litter in the bowl cut cleaning and blockages. Staff who clean should know which products to use, and which to avoid in a waterless unit. A short instruction sheet on the wall of the cleaner's cupboard is cheap and effective.
Choosing a flush control
Urinals can be flushed by a manual push valve, a cistern with an automatic timer, a sensor or a waterless design. A manual valve is sturdy and cheap but depends on the user. A timed cistern flushes whether or not anyone is there, which wastes water in a quiet building. A sensor flushes after use, which saves water and keeps the bowl cleaner, but needs power or batteries and regular cleaning of the sensor window. Think about who will clean and service each, because a flush control that nobody looks after is a source of smell and complaints. We help you choose for the building.
How much does urinal installation cost in Dubai?
In Dubai, the price follows these items:
- The urinal and flush device. A bowl, a stall or a trough, and a manual, sensor or waterless flush.
- The visit and diagnosis. The visit fee is AED 50 + VAT, and it comes off the bill when you go ahead with the work.
- Labour. Isolation, removal, fitting and testing.
- Rough-in work. Waste and supply positions, and chasing or making good the wall.
- Sensor, power and batteries. The valve's power and any wiring, by our own electricians.
- Accessible fit-out. Grab bars and floor-reaching bowls where the project requires them.
- Drain work. A check or clearance of the line below, and for a waterless retrofit, the cleaning of the drain first.
- Access and hours. A tenant fit-out that restricts working hours, or a working washroom that must be closed.
We do not publish a starting price for this job. Send a photo on WhatsApp and we give you a fixed price before we start. Prices exclude 5% VAT.
Urinal FAQs
What types of urinal are there?
Wall-hung bowls, floor-reaching stalls, troughs and rimless designs. Flushing can be a manual valve, a sensor, a timer, a cistern, or none at all in a waterless model. See the types section above.
How high should a urinal be fitted?
At the rim height on the maker's rough-in sheet for your model, and on the fit-out drawings where there are any. A children's washroom or an accessible urinal is set differently, and we ask for the drawing first.
How far apart should urinals be?
Far enough that users do not crowd each other, and the building's fit-out rules or the maker's sheet can ask for more. Check them before the pipework is roughed in, because the spacing is fixed once the waste is in the wall.
How much water does a urinal use?
A standard flushing urinal uses a modest amount per flush, a water-saving model less, and a waterless one none. The volume is set at the flush valve or cistern, and the sensor or timer sets how often it runs.
Why does my urinal smell?
The cause is usually the user side or the cleaning method, a trap that has dried out, a waterless cartridge that is overdue, or a blocked drain below. We check the user side first, then the trap, then the drain.
How often should a waterless cartridge be changed?
By the maker's schedule, which is commonly every few months or after a set number of uses, whichever comes first. We follow the data sheet for your cartridge and record the date.
Why does my sensor urinal not flush?
The usual causes are a flat battery, a dirty sensor window, a closed isolating valve or a solenoid valve blocked with debris. Check the battery and the valve first, wipe the sensor, then test the solenoid. We replace the sensor, the battery pack and the solenoid.
Why does my urinal keep running?
The usual causes are debris at the diaphragm, low line pressure, a damaged diaphragm assembly or a solenoid stuck open. Close the isolation valve and call.
Can I put a urinal in a villa or apartment?
It would be an alteration to the waste and supply, so a rented home needs the landlord's written consent, and an owned flat needs building management. This is not legal advice.
Does FAM fit squat toilets?
Yes. A pan set into the floor needs depth below the floor for its trap, so we look at the slab and the ceiling below before we quote. See the squat toilets section above.
How much does urinal installation cost in Dubai?
We do not publish a starting price for this job. Send a photo on WhatsApp and we give you a fixed price before we start. Prices exclude 5% VAT.
Book a urinal installation or repair in Dubai
Tell us what the urinal is doing, or the type you want, the flush device, whether the premises are leased or owned, and the floor. Photos of the urinal, its model number, the valve and the wall help. If water is leaking, close the isolation valve and call. We will check the supply and drain, fit or repair the urinal, test the flush and every joint, and give you a written note.
WhatsApp: +971 55 407 7427 · Request a quote
Visit us: Office 871, Oasis Mall, Al Quoz 1, Dubai, UAE
Related services: Toilet installation · Toilet repair · Toilet unblocking · Backflow prevention · Drain unblocking · Valve repair and replacement · Pressure reducing valves